Agenda item

17/01464/FULM - Grand Hotel, Broadway, Leigh-on-Sea, Essex, SS9 1PJ (Leigh Ward)

Minutes:

Proposal:  Convert existing hotel into mixed use comprising basement wine bar and health club, ground floor restaurants and terrace, 18 self-contained flats on three floors, demolish existing mansard roof and form new replacement mansard roof, erect three storey rear extension with mansard roof, install balconies to rear and sides at first floor and third floor level, external alterations, install extract/ventilation equipment and solar PV panels on roof, layout additional parking, associated landscaping and communal roof terrace and form vehicular access onto Broadway (Amended Proposal)

Applicant:  460 Leisure Ltd

Agent:  Smart Planning

 

MS P Godfrey, a local resident, spoke as an objector to the application.  Mr Dadds, the applicant’s solicitor, responded.

 

Resolved:  (a) That the Deputy Chief Executive (Place), Director of Planning and Transport or Group Manager of Planning & Building Control be DELEGATED to GRANT PLANNING PERMISSION, subject to completion of an AGREEMENT UNDER SECTION 106 of the Town and Country Planning Act 1990 (as amended) and all of the appropriate legislation to secure the provision of:

 

  A financial contribution towards secondary education provision of £9,607.57 (index-linked), specifically providing increased capacity at Belfairs Academy which is payable prior to commencement;

  A financial contribution of £2500 to cover the cost of amending the Traffic Regulation Order to accommodate the new vehicular access ;

  The provision of Travel Packs for the commercial uses.

 

(b) The Director of Planning and Transport or the Group Manager (Planning & Building Control) be authorised to determine the application upon completion of the above obligation, so long as planning permission when granted and the obligation when executed, accords with the details set out in the report submitted and the conditions listed below:

 

01.  The development hereby permitted shall be begun not later than 3 years beginning with the date of this permission.

 

Reason: Required to be imposed pursuant to Section 91 of the Town and Country Planning Act 1990

 

02.  The development shall be carried out in accordance with the approved plans:  1391-14A,  1622-01; 1622-02G; 1622-03J; 1622-04K; 1622-05L; 1622-06H;  1622-07E; 1622-08D; 1622-09D; 1622-11B; 1622-12A; 1622-25, Soft Landscape Plan; Location Plan

 

Reason: To ensure the development is carried out in accordance with the development plan.

 

03.  Prior to the commencement of development samples and / or product details of the materials to be used in the construction / alteration of the external elevations of the development hereby permitted, including bricks (sample required), tiles (sample required), roof materials, stonework (sample required) cladding (sample required) balconies and balustrades, windows and doors including doors and gates to storage areas, dormers,  hardstanding and terrace paving, steps and ramp, boundary railings and boundary wall have been submitted to and approved in writing by the local planning authority. The development shall be carried out in accordance with the approved details before it is brought into use.

 

Reason: To safeguard character and appearance of the locally listed building surrounding Leigh Cliff Conservation Area in accordance with Policies KP2 and CP4 of the Core Strategy (2007) and Policies DM1, DM3 and DM5 of the Development Management Document  (2015) and advise contained within the Southend Design and Townscape Guide (2009).

 

04.  Prior to the commencement of development, a sample panel showing the pointing profile, copings, mortar mix, bricks and brick bond to be used on the extension and brick wall shall be submitted to and agreed in writing by the local planning authority. The works shall be carried out only in accordance with the agreed details unless otherwise first agreed in writing with the Local Planning Authority.

 

Reason: To safeguard character and appearance of the locally listed building surrounding Leigh Cliff Conservation Area in accordance with Policies KP2 and CP4 of the Core Strategy (2007) and Policies DM1, DM3 and DM5 of the Development Management Document (2015) and advise contained within the Southend Design and Townscape Guide (2009).

 

05.  Prior to the commencement of development, detailed drawings, including all styles of doors and windows, balustrades, balconies and railings, dormers, mansard ridge detail, stonework (window surrounds and boundary wall copings), dormer details including decorative pediments, chimney and parapet detail for the extension and details of the  staircase access/lift shaft at roof level at scales of 1:20, 1:10 or 1:1 as appropriate shall be submitted to and agreed in writing by the local planning authority. The development shall only be carried out and in accordance with the approved details.

 

Reason: To safeguard character and appearance of the locally listed building surrounding Leigh Cliff Conservation Area in accordance with Policies KP2 and CP4 of the Core Strategy (2007) and Policies DM1, DM3 and DM5 of the Development Management Document  (2015) and advise contained within the Southend Design and Townscape Guide (2009).

 

06.  Prior to the commencement of development of the front terrace hereby approved, details of the junction between the existing building and the proposed terrace, the ramp and the terrace wall/balustrade shall be submitted to and agreed in writing by the local planning authority. The development shall be carried out only in accordance with the approved details.

 

Reason: To safeguard character and appearance of the locally listed building surrounding Leigh Cliff Conservation Area in accordance with Policies KP2 and CP4 of the Core Strategy (2007) and Policies DM1, DM3 and DM5 of the Development Management Document  (2015) and advise contained within the Southend Design and Townscape Guide (2009).

 

07.  No electricity, gas or water meter boxes, soil ventilation pipes, air extraction pipes, air conditioning units, boiler flues, ventilation grills or ducting shall be fixed to the exterior of the building other than in accordance with details that have been submitted to and approved in writing by the local planning authority.

 

Reason: To safeguard character and appearance of the locally listed building surrounding Leigh Cliff Conservation Area in accordance with Policies KP2 and CP4 of the Core Strategy (2007) and Policies DM1, DM3 and DM5 of the Development Management Document  (2015) and advise contained within the Southend Design and Townscape Guide (2009).

 

08.  Notwithstanding the details shown on the plans submitted and otherwise hereby approved, no construction works above a lower ground floor slab level shall take place until full details of both hard and soft landscape works and proposed boundary treatment have been submitted to and approved in writing by the local planning authority.  These details shall include: proposed finished levels or contours; means of enclosure, car parking layouts;  other vehicle and pedestrian access and circulation areas;  hard surfacing materials;  minor artefacts and structures (e.g. furniture, loggia, bollards, play equipment, refuse or other storage units, signs, lighting etc.)  Details for the soft landscape works shall include the number, size and location of the trees, shrubs and plants to be planted together with a planting specification and the initial tree planting and tree staking details. 

 

The hard landscaping shall be implemented in full accordance with the approved details before the development is occupied or brought into use. The soft landscaping shall be completed before the end of the first planting season following first occupation of the building.

 

Reason: In the interests of visual amenity and the amenities of occupiers and to ensure a satisfactory standard of landscaping pursuant to Policy CP4 of the Core Strategy (2007) and policies DM1, DM3 and DM5 of the Development Management Document (2015) and advise contained within the Southend Design and Townscape Guide (2009).

 

09.  No construction works above a lower ground floor slab level shall take place until a landscape management plan, including long term design objectives, management responsibilities and maintenance schedules for all landscape areas, has been be submitted to and approved by the Local Planning Authority prior to the occupation of the development.  The landscaping of the site shall be managed in accordance with the approved plan from occupation in perpetuity.

 

Reason: In the interests of visual amenity and the amenities of occupiers and to ensure a satisfactory standard of landscaping pursuant to Policy CP4 of the Core Strategy (2007) and policies DM1, DM3 and DM5 of the Development Management Document (2015) and advise contained within the Southend Design and Townscape Guide (2009).

 

10.  Prior to the commencement of the development details of tree protection measures, in relation to the cedar tree to the front, shall be submitted to and approved by the local planning authority. The approved tree protection measures shall be implemented in full prior to commencement of the development and be retained throughout construction unless otherwise agreed in writing with the local planning authority.

 

Reason: To ensure the cedar tree to the front of the site is adequately protected during building works in the interests of visual amenity and in accordance with Core Strategy (2007) policies KP2 and CP4, Development Management Document (2015) policy DM1 and advice contained within the Southend Design and Townscape Guide (2009).

 

11.  The development shall not be occupied or brought into use until space has been laid out within the site in accordance with drawing No. 1622-02G for 28 cars to be parked and for vehicles to turn so that they may enter and leave the site in a forward gear.  The parking spaces shown in the approved plans shall be permanently retained only thereafter for the parking of occupiers, staff and visitors to the development. 

 

Reason: To ensure that adequate car parking is provided and retained to serve the development in accordance with Policy CP3 of the Core Strategy (2007) and Policy DM15 of the Development Management (2015).

 

12.  The development shall not be occupied or brought into use until the refuse and recycling  storage facilities are provided in full within the details shown on approved site in accordance with drawing No. 1622-02G . The refuse and recycling facilities shall be permanently retained as such thereafter. 

 

Reason:  To ensure that the development is satisfactorily serviced and that satisfactory waste management is undertaken in the interests of highway safety and visual amenity and to protect the character of the surrounding area, in accordance with Policies KP2 and CP3 of the Core Strategy DPD1 and  Policy DM15 of the Development Management DPD 2015.

 

13.  The development shall not be occupied or brought into use until a waste management plan and service plan has been submitted to and agreed in writing by the Local Planning Authority.  The waste management and servicing of the development shall thereafter only be carried out in accordance with the approved details.

 

Reason:  to ensure that the development is satisfactorily serviced and that satisfactory waste management is undertaken in the interests of highway safety and visual amenity and to protect the character of the surrounding area, in accordance with Policies KP2 and CP3 of the Core Strategy DPD1 and  Policy DM15 of the Development Management DPD 2015.

 

14.  A scheme detailing how at least 10% of the total energy needs of the development will be supplied using on site renewable sources shall be submitted to and agreed in writing by the Local Planning Authority prior to commencement of the development and implemented in full prior to the first occupation of the development. This provision shall be made for the lifetime of the development.

 

Reason: In the interests of providing sustainable development in accordance with Policy KP2 of the Core Strategy (2007) and Development Management Document (2015) policy DM2.

 

15.  Prior to the commencement of the development details of any extraction and ventilation equipment to be installed at the site shall be submitted to and approved in writing by the Local Planning Authority. The scheme as approved shall be implemented before the basement and ground floor commercial space is brought into use. All equipment installed as part of the scheme shall thereafter be operated and maintained in accordance with the manufacturer's instructions.

 

Reason: In order to protect the amenities of occupiers of the development surrounding occupiers and to protect the character and visual amenities of the area in accordance with policies KP2 and CP4 of the Core Strategy DPD1 and Policies DM1 and DM3 of the Development Management DPD 2015.

 

16.  With reference to BS4142, the noise rating level arising from all plant and extraction/ventilation equipment installed at the site shall be at least 5dB(A) below the prevailing background at 3.5 metres from ground floor façades of the nearest noise sensitive property and 1 metre from all other façades of the nearest noise sensitive property with no tonal or impulsive character. 

 

Reason: In order to protect the amenities of occupiers of the development and surrounding residents in accordance with policies KP2 and CP4 of the Core Strategy (207) and Policies DM1 and DM3 of the Development Management Document  2015.

 

17.  A Noise Management Plan in respect of the non-residential uses hereby approved shall be submitted to and agreed in writing by the Local Planning Authority prior to the first use of non- residential uses herby approved. The Noise Management Plan shall include measures to reduce noise transmission from the outdoor terrace area which may cause a nuisance to neighbouring properties including a prohibition on amplified music being played within this terrace area. The non-residential uses at the site shall be managed and operated in full accordance with the measures in the approved Noise Management Plan from them being first brought into use and in perpetuity thereafter.

 

Reason: In order to protect the amenities of occupiers of the development and surrounding occupiers in accordance with policies KP2 and CP4 of the Core Strategy (207) and Policies DM1 and DM3 of the Development Management Document  2015.

 

18.  There shall be no new orders for dining on the front terrace from 22:30 until the close of business that day and the entire front terrace area cleared of all customers by 23:00 until the close of business that day. Additionally all doors accessing the terrace shall be closed, except temporarily for access and egress, from 23:00 to 08:30.

 

Reason: In order to protect the amenities of occupiers of the development and surrounding occupiers in accordance with policies KP2 and CP4 of the Core Strategy (207) and Policies DM1 and DM3 of the Development Management Document  (2015).

 

19.  Notwithstanding the details specified in the submitted acoustic report by SRL dated 20th July 2016, prior to the commencement of the development, an amended acoustic report that also includes an assessment of the noise potential of the function room and health club and which includes recommendations for mitigation measures for these areas shall be submitted and agreed in writing with the local planning authority. These uses in the scheme shall be managed and operated in full accordance with the measures in the approved report from them being first brought into use and in perpetuity thereafter. 

 

Reason: In order to protect the amenities of the first floor flat occupiers of the development and surrounding occupiers in accordance with policies KP2 and CP4 of the Core Strategy (207) and Policies DM1 and DM3 of the Development Management Document  2015.

 

20.  The class A4 (wine bar) use hereby permitted in the basement shall not be open to customers outside the following times: 09:00 to 01:00 on Monday to Saturdays and 09:00 to 23:00 on Sundays and Bank Holidays.

 

Reason: In order to protect the amenities of occupiers of the development and surrounding residential area from noise associated with patrons leaving the establishment and smokers congregating outside during opening times in accordance with policies KP2 and CP4 of the Core Strategy DPD1 and Policies DM1 and DM3 of the Development Management DPD 2015.

 

21.  The restaurant, brasserie and function room use hereby permitted at ground floor shall not be open to customers outside the following times: 09:00 to 01:00 on Mondays to Saturdays and 09:00 to 23:00 on Sundays and bank holidays and the French doors to access these areas shall be kept closed from 23:00 to 09:00.

 

Reason: In order to protect the amenities of occupiers of the development and surrounding residential area from noise associated with patrons leaving the establishment and smokers congregating outside during opening times in accordance with policies KP2 and CP4 of the Core Strategy DPD1 and Policies DM1 and DM3 of the Development Management DPD 2015.

 

22.  Notwithstanding the provisions of the Town and Country Planning (General Permitted Development) Order 2015 (as amended) or any revocation, amendment or adaptation of this legislation of for the time being maybe in force, the basement floorspace hereby approved and identified as the Health Club area, as shown on plan No 1662-.9D, shall only be used as a health club (class D2) and for no other purpose whatsoever.

 

Reason: In order to protect the amenities of occupiers of the development and surrounding occupiers in accordance with policies KP2 and CP4 of the Core Strategy (207) and Policies DM1 and DM3 of the Development Management Document  (2015).

 

23.  The basement floorspace hereby approved and identified as the  Health Club, as shown on plan No 1662-.9D shall not be used outside of the following hours: 07:00 to 23:00 Mondays to Sundays.

 

Reason: In order to protect the amenities of occupiers of the development and surrounding occupiers in accordance with policies KP2 and CP4 of the Core Strategy (207) and Policies DM1 and DM3 of the Development Management Document  (2015).

 

24.  No deliveries or refuse collection shall be taken at or despatched from the non-residential uses herby approved outside the hours of 07:00 to19:00hours Mondays to Fridays and 08:00 to 13:00 hours on Saturdays nor at any time on Sundays, Bank or Public Holidays.

 

Reason: In order to protect the amenities of occupiers of the development surrounding occupiers and to protect the character and amenities of the area in accordance with policies KP2 and CP4 of the Core Strategy (2007) and Policies DM1 and DM3 of the Development Management Document (2015).

 

25.  No external lighting shall be installed on the building other than in accordance with details that have previously been submitted to and approved in writing by the local planning authority.  No additional external lighting shall be installed on the building or within the site without the prior written consent of the Local Planning Authority. 

 

Reason: In the interest of the visual amenities and character of the conservation area, and to protect the amenities of surrounding occupiers in accordance with policies  KP2 and CP4 of the Core Strategy (2007) and Policies DM1 and DM5 of the Development Management Document (2015).

 

26.  Notwithstanding the details shown on the plans submitted and otherwise hereby approved, the development shall not be occupied until details of the secure, covered cycle parking spaces to serve the residential development and separate secure covered cycle parking spaces to serve the commercial uses and additional external visitor cycle parking have been submitted to and agreed in writing by the local planning authority. The approved cycle parking shall be implemented in full prior to first occupation of the development and shall be permanently retained thereafter for the storage of cycles. 

 

Reason: To ensure that adequate cycle parking is provided and retained to serve the development in accordance with Policies CP3 of the Core Strategy (2007) and Policy DM15 of the Development Management Document (2015).

 

27.  No development shall take place, including any works of demolition, until a Construction Method Statement has been submitted to, and approved in writing by, the local planning authority. The approved Statement shall be adhered to in full throughout the construction period. The Statement shall provide, amongst other things, for:

 

i)  the parking of vehicles of site operatives and visitors

ii)  loading and unloading of plant and materials

iii)  storage of plant and materials used in constructing the development

iv)  the erection and maintenance of security hoarding 

v)  measures to control the emission of dust and dirt during construction

vi)  a scheme for recycling/disposing of waste resulting from demolition and construction works that does not allow for the burning of waste on site.

 

Reason: In the interests of visual amenity and the amenities of occupiers and to ensure a satisfactory standard of landscaping pursuant to Policy CP4 of the Core Strategy (2007) and Policy DM1 of the Development Management Document (2015).

 

28.  Demolition or construction works associated with this permission shall not take place outside 08:00 hours to 18:00 hours Mondays to Fridays and 08:00 hours to 13:00 hours on Saturdays and at no time Sundays or Bank Holidays.

 

Reason: In order to protect the amenities of occupiers of the development surrounding occupiers and to protect the character the area in accordance with policies KP2 and CP4 of the Core Strategy (2007) and Policies DM1 and DM3 of the Development Management Document (2015).

 

29.  Notwithstanding the provisions of the Town and Country Planning (General Permitted Development) Order 2015 (as amended) (or any order revoking, re-enacting or modifying that Order), no structures such as canopies, fences, loggias, trellises or satellite or radio antennae shall be installed within the development or on the buildings hereby approved unless otherwise previously agreed in writing by the Local Planning Authority. 

 

Reason: In order to protect the character and visual amenities of the locally listed building and surrounding conservation area and airport safety in accordance with policies KP2 and CP4 of the Core Strategy (2007) and Policy DM1 of the Development Management Document (2015).

 

30.  No development shall take place until details of the implementation, maintenance and management of a scheme for surface water drainage works (incorporating Sustainable Urban Drainage (SuDs) Principles) have been submitted to and approved by the local planning authority. The approved scheme shall be implemented,  in accordance with the approved details before the development is occupied or brought into use and be maintained as such thereafter in perpetuity. Those details shall include:

 

i)  An investigation of the feasibility of infiltration SUDS as the preferred approach to establish if the principles of any infiltration based surface water drainage strategy are achievable across the site, based on ground conditions.  Infiltration or soakaway tests should be provided which fully adhere to BRE365 guidance to demonstrate this.  Infiltration features should be included where infiltration rates allow; 

ii)  Drainage plans and drawings showing the proposed locations and dimensions of all aspects of the proposed surface water management scheme.  The submitted plans should demonstrate the proposed drainage layout will perform as intended based on the topography of the site and the location of the proposed surface water management features; 

iii)  a timetable for its implementation; and

vii)  a management and maintenance plan for the lifetime of the development which shall include the arrangements for adoption by any public body or statutory undertaker, or any other arrangements to secure the operation of the sustainable drainage scheme throughout its lifetime.

 

Reason: To prevent flooding by ensuring the satisfactory storage and disposal of surface water from the site for the lifetime of the development and to prevent environmental and amenity problems arising from flooding in accordance with Policy KP2 and CP4 of the Core Strategy (2007) and  Policy DM2 of the Development Management Document  (2015)

 

31.  Prior to occupation of the flats hereby approved, appropriate water efficient design measures as set out in Policy DM2 (iv) of the Development Management Document to limit internal water consumption to not more than 105 litres per person  per  day  (lpd)  (110  lpd  when  including  external  water  consumption), to include measures of water efficient fittings, appliances and water recycling systems such as grey water and rainwater harvesting shall be implemented for the development and thereafter retained in perpetuity.

 

Reason:  To minimise the environmental impact of the development through efficient use of water in accordance with the National Planning Policy Framework, Core Strategy (2007) Policy KP2, Development Management Document (2015) Policy DM2 and Design and Townscape Guide (2009).

 

32.  Prior to the commencement of the development details shall be submitted to the local planning authority and approved in writing specifying the measure that shall be put in place to ensure that the chimneys on the existing building shall be able to be retained in full. The development shall be implemented only in accordance with the details approved under this condition.

 

Reason: To safeguard character and appearance of the locally listed building surrounding Leigh Cliff Conservation Area in accordance with Policies KP2 and CP4 of the Core Strategy (2007) and Policies DM1, DM3 and DM5 of the Development Management Document (2015) and advise contained within the Southend Design and Townscape Guide (2009).

 

The Local Planning Authority has acted positively and proactively in determining this application by identifying matters of concern within the application (as originally submitted) and negotiating, with the Applicant, acceptable amendments to the proposal to address those concerns.  As a result, the Local Planning Authority has been able to grant planning permission for an acceptable proposal, in accordance with the presumption in favour of sustainable development, as set out within the National Planning Policy Framework.  The detailed analysis is set out in a report on the application prepared by officers.

 

Informatives

 

01.  Please note that the development the subject of this application is liable for a charge under the Community Infrastructure Levy Regulations 2010 (as amended). A Community Infrastructure Levy (CIL) Liability Notice will be issued as soon as practicable following this decision notice. This contains details including the chargeable amount, when this is payable and when and how exemption or relief on the charge can be sought. You are advised that a CIL Commencement Notice (CIL Form 6) must be received by the Council at least one day before commencement of development. Receipt of this notice will be acknowledged by the Council. Please ensure that you have received both a CIL Liability Notice and acknowledgement of your CIL Commencement Notice before development is commenced. Most claims for CIL relief or exemption must be sought from and approved by the Council prior to commencement of the development. Charges and surcharges may apply, and exemption or relief could be withdrawn if you fail to meet statutory requirements relating to CIL. Further details on CIL matters can be found on the Council's website at www.southend.gov.uk/cil.

 

02.  The applicant is reminded that this permission does not bestow compliance with other regulatory frameworks. In particular your attention is drawn to the statutory nuisance provisions within the Environmental Protection Act 1990 (as amended) and also to the relevant sections of the Control of Pollution Act 1974. The provisions apply to the construction phase and not solely to the operation of the completed development. Contact 01702 215005 for more information.

 

03.  The applicant is advised that an application to discharge trade effluent must be made to Anglian Water and must have been obtained before any discharge of trade effluent can be made to the public sewer. Anglian Water recommends that petrol / oil interceptors be fitted in all car parking/washing/repair facilities. Failure to enforce the effective use of such facilities could result in pollution of the local watercourse and may constitute an offence.  Anglian Water also recommends the installation of a properly maintained fat traps on all catering establishments. Failure to do so may result in this and other properties suffering blocked drains, sewage flooding and consequential environmental and amenity impact and may also constitute an offence under section 111 of the Water Industry Act 1991

 

04.  Please note that if you require crane of piling rig to construct the proposal, this will need to be safeguarded separately and dependant on location may be restricted in height and may also require full coordination with the Airport Authority.

 

05.  This permission is governed by a legal agreement between the applicant and the Borough Council under Section 106 of the Town and Country Planning Act 1990. The agreement relates to a financial contribution towards affordable housing and secondary education.

 

06.  In the event that the planning obligation referred to in part (a) above has not been completed by 16th November or an extension of this time as may be agreed the Director of Planning and Transport or Group Manager (Planning & Building Control) be authorised to refuse planning permission for the application on the grounds that the development will not provide for education provision. As such, the proposal would be contrary to Policies KP2, KP3 and CP6

 

07.  The applicant is advised that 18 cycle spaces are required for the residential cycle store and 1 space per 100 sqm for the staff of the A3 and A4 uses (which equates to 6 spaces) as well as 10 spaces for the staff of the D2 use which need to be provided within a segregated secure store. In addition to this there is also a requirement for 1 space per 100 sqm for visitors of A3 and A4 uses which may be located in the external area.

Supporting documents:

 

Get the best from this site

We use simple text files called 'cookies'. Some of these cookies are essential to make our site work and others help us to improve by giving us some insight into how the site is being used. For more information, including how to turn cookies off, see more about cookies - or simply click the Continue button to use this site as normal.